Data Parameters Long Parameter Names
FLI
Shows the nominal fuel tank liquid fill capacity. For gaseous fuels the
percentage of usable fuel capacity is shown. Can be obtained directly from a
dedicated sensor or calculated by the ECM from other sensor signals.
FRP
Shows the fuel rail pressure at the engine relative to the atmosphere
(gauge pressure).
FRP_REL
Shows the fuel rail pressure measured at the engine relative to the intake
manifold vacuum.
FUELSYSx
Fuel System 'x' does not normally refer to injector banks. It is intended to
represent different fuel systems (for multi-fuel vehicles) that independently enter
and exit 'Closed Loop'. 'Closed Loop' means the fuel control system uses the
oxygen sensor signal. Banks of injectors on a V-type engine are generally not
independent and use the same closed loop criteria.
IAT
Shows the intake manifold air temperature as obtained from a sensor or as
calculated by the ECM (using other inputs).
LOAD_ABS
Value is presented as a percentage and ranges from 0 to 100 for naturally
aspirated engines, and from 0 to 400 for boosted engines.
On boosted engines the actual figure displayed depends upon how much boost
is used. The higher the boost used, the higher the Absolute Load Value will be.
LOAD_PCT
The ECM calculates the engine load by dividing the actual manifold airflow
volume (Otto engines) or actual fuel flow (Diesel engines) by the maximum
possible volume with a factor for pressure and temperature compensation.
Correlates with the engine vacuum. Value is presented as a percentage and
ranges from 0 to 100.
LONGFTx
Shows the correction used by the Closed Loop and Open Loop fuel algorithm at
the moment this parameter is requested. Negative values indicate a 'lean'
condition, positive values a 'rich' condition. 0% correction will be shown if no
correction is used in Open Loop.
MAF
Shows the flow rate of the intake air as measured by the Mass Air Flow
(MAF) sensor.
MAP
Shows the absolute pressure in the intake manifold as measured by the
MAP sensor.
MIL_DIST
Conditions for this counter:
1. Resets to zero when MIL state changes from 'deactivated' to 'activated' by the
ECM.
2. Accumulates counts in km if MIL is activated (ON)
3. Does not change value while MIL is not activated (OFF)
4. Resets to zero if diagnostic information is cleared either by service $04 or 40
warm-up cycles without MIL activated
5. Does not wrap to zero if value is maximum (65535).
MIL_TIME
Conditions for this counter:
1. Resets to zero when MIL state changes from deactivated to activated by
the ECM.
2. Accumulates counts in minutes if MIL is activated (ON).
3. Does not change value while MIL is not activated (OFF).
4. Resets to zero if diagnostic information is cleared either by service $04 or 40
warm-up cycles without MIL activated.
5. Does not wrap to zero if value is maximum (65535).
O2SLOCxy
Shows the presence of oxygen sensor number 'y' per bank 'x' (group of
cylinders). Sensor 1 is closest to the engine
Table 7-2 Short parameter names (sheet 2 of 3)
Parameter Description for short parameter